Sleep Europe 2026: findings from the sleep congress
Manuel Schabus | 19.11.2026

From 20 to 23 October 2026, European sleep research met in Maastricht: Sleep Europe 2026, the 28th congress of the European Sleep Research Society (ESRS). Univ.-Prof. Dr. Manuel Schabus, head of the Laboratory for Sleep, Cognition and Consciousness Research at the University of Salzburg and scientific co-founder of sleep², was there with his team. This time the Salzburg group did not just listen but presented nine posters of its own.
One thread runs through almost every topic: away from the single snapshot, towards the course over many nights. Here are the six findings we consider most important. All of our own contributions are available in the original at sleepscience.at/posters. They are congress contributions and therefore not yet peer-reviewed.
1. The gold standard is fuzzier than assumed
Polysomnography (PSG) in the sleep lab is regarded as the gold standard. In the end, a trained scorer decides for every 30-second segment whether it is wake, N1, N2, N3 (deep sleep) or REM sleep. Peter Anderer and colleagues showed how much judgement goes into this: the share of segments on which all scorers agree falls with every additional scorer, from 71 percent with two to 32 percent with twelve (Bakker et al., 2023, SLEEP). In one single night of a 76-year-old patient with sleep apnoea, twelve experts found between 0 and 67 minutes of deep sleep.
The field's answer is the hypnodensity: instead of assigning exactly one stage to each segment, it gives probabilities, for example 60 percent N2 and 40 percent N1 (Anderer et al., 2023, Frontiers in Sleep). The keynote by Delphine Oudiette (Paris Brain Institute) also came down to describing sleep in probabilities rather than rigid categories. sleep² already computes such stage probabilities and provides them for research and clinical use on request.
“In sleep, a lot is relative. Consciousness, too, is not simply on or off. It is graded.”
Univ.-Prof. Dr. Manuel Schabus, scientific co-founder of sleep²
2. One night is not enough
The finding with the clearest practical relevance came from Danny Eckert (Flinders University, Adelaide). In data from 3,831 adults with at least 28 nights measured at home, his team simulated 1,000 studies. When the apnoea-hypopnoea index (AHI) was taken from a single night, the association between sleep apnoea and new-onset hypertension went undetected in 42 percent of the simulations, in 5 percent with seven nights, and never from 28 nights onwards (Lechat et al., 2023, Chest). These are observational data, mostly from men. The direction is clear nonetheless.
Anyone who measures over many nights has to be able to rely on the measuring device itself staying stable. That is exactly what Carina Mitterer from our group tested: 18 adults, five nights at home, eight sleep trackers simultaneously against PSG, each worn on the left and on the right. Whether the night was normal, shortened and disturbed, or extended: agreement with PSG remained practically unchanged, and only one of 32 comparisons differed from the normal night. Body side made no difference either for six of seven devices (Mitterer et al., poster). Accuracy is therefore a property of the device, not of the night.
“You actually need multiple nights for an accurate diagnosis.”
Univ.-Prof. Dr. Manuel Schabus
3. What the heart reveals at night
The closing talk by Magnus Ruud Kjær (Technical University of Denmark and Stanford University) presented SleepFM, an AI model that was trained on around 585,000 hours of polysomnography and estimates the later onset of 130 disease categories. The heart signal alone was usually only slightly below the best single signal (Thapa, Kjær et al., 2026, Nature Medicine). Such values describe risk in groups, not a diagnosis for the individual.
Two Salzburg contributions point in the same direction. Sebastian Baron trained a model on 8,582 laboratory nights to estimate the severity of sleep apnoea from heartbeat intervals alone. It assigned around 75 percent of the recordings to the correct one of four severity classes, and 74 percent in an independent dataset of 70 recordings; the estimated AHI deviated by 4.4 events per hour on average. A detour was decisive: the model first learned the hypoxic burden, which captures the depth and duration of oxygen desaturations in addition to their number. Without this step, the hit rate was around 49 percent. The limits are stated: so far the model has been trained on ECG data from the lab, cardiac arrhythmias or beta blockers can weaken the signal, and the method is suited as an early warning, not as a diagnosis (Baron et al., poster).
Pavlos Topalidis tested the method behind sleep² in a particularly difficult group: 26 epilepsy patients with implanted brain electrodes, in whom the EEG is hard to score. From a single ECG channel, 72 percent of the segments agreed with expert scoring. Wake and light sleep were recognised around 75 percent of the time, deep sleep (48 percent) and REM (59 percent) markedly less well (Topalidis et al., poster). Sleep times and sleep continuity can be tracked this way; deep sleep and REM need refinement.
4. Sleep trackers put to the test
How well common devices measure under everyday conditions is shown by the poster on the Salzburg comparison study: eight trackers, 85 nights with analysable PSG at home, including one night with shortened sleep and a 20-minute scheduled awakening. sleep² reached around 84 percent agreement for four sleep stages with both the Polar H10 and the Polar Verity Sense, while the other devices ranged from around 56 to 73 percent (Topalidis et al., poster).
The biggest weakness of almost all devices is lying quietly awake. Depending on the tracker, 23 to 49 percent of wake segments were scored as light sleep, compared with 18 to 19 percent for sleep². The consequence: most devices overestimate sleep duration, some by more than half an hour. All eight noticed the scheduled awakening, but seven showed less wake time than PSG measured (Mitterer et al., poster). A limitation: the participants were young, healthy adults, and the study comes from our own group, without manufacturer funding and with open analysis code. More in the article on the Salzburg comparison study.
5. Insomnia therapy: measurement data help, but not automatically
Does sleep tracking make digital cognitive behavioural therapy for insomnia (CBT-I) better? Alexandra Hinterberger presented the interim status of an ongoing randomised trial with 46 patients: one group used the sleep² app with therapy programme, sleep diary, sleep measurement and daily feedback, the other only programme and diary. Insomnia complaints decreased markedly and to a similar extent in both groups. The engine is therefore the therapeutic content.
The feedback had two sides. Self-assessment tended to move closer to the measured values, for example for sleep efficiency. At the same time, the feedback group reported more night-time awakenings over time, the comparison group did not, and in a first, purely descriptive analysis it rated the app as more helpful but also as somewhat more burdensome (Hinterberger et al., poster). Who benefits from measurement data and who is better off without is currently being analysed.
That digital CBT-I also works during menopause is suggested by a first interim look at the Dutch study “Sleeping Through Menopause” (VU Amsterdam, 68 of 222 planned participants): complaints decreased with digital therapy, most strongly in combination with hormone therapy. More in our guide to insomnia and sleep disorders.
6. 23,000 nights: sleep under extreme conditions
What sleep looks like under high strain is shown by a study with the Jagdkommando, the Austrian special operations forces: 71 service members, 68 weeks, 23,641 nights with sleep² and a Polar sensor. Before the interventions began, they slept around 15 minutes less than comparable sleep² users, fell asleep faster and lay awake for less time at night. That sounds like good sleep, but it is a sign of high sleep pressure.
During the interventions (digital CBT-I in the app, later personal coaching and ergonomic mattresses, and dietary supplements in a second group), sleep remained stable, while in the control group it became more restless over the months. Combat training cost service members over 35 markedly more sleep quality than younger ones. And before a shooting test, measured sleep in the preceding night distinguished those who passed from the rest, whereas self-rated sleep did not (Schabus et al., poster). These are associations, not evidence of cause and effect.
In brief
A nap is not a short night
A model trained for the night loses accuracy during the day: from 85 to 72 percent. After retraining with 112 daytime sleep recordings it was back at around 83 percent, also with wearable sensors (Baron et al., poster). In a second study with 15 people, daytime sleep after a shortened night was around 17 minutes longer and deeper, and sleep² captured this change similarly to PSG. Mood did not improve after the nap; positive mood even decreased slightly (Predko et al., poster).
Heat costs sleep
In more than 165 million measured nights, people slept 15 to 17 minutes less at an outside temperature of 27 °C than at 12 °C (Lechat et al., 2025, SLEEP). During European heatwaves, moderate to severe sleep apnoea also increased (Pinilla et al., 2025, European Respiratory Journal).
Sleep shapes the brain from the very beginning
In 50 newborns aged two weeks, an EEG measure regarded as an indicator of the balance between excitation and inhibition depended strongly on sleep stage. Children with mid-range values had the highest communication scores in a parent questionnaire at twelve months (Schabus et al., poster).
What this means for sleep measurement at home
Maastricht paints a clear picture. A single night is a snapshot, even in the lab. Sleep stages are better described as probabilities. And the heart signal carries more information than it was long given credit for.
sleep² works on this principle: with a Polar sensor on the upper arm or chest, the app computes four sleep stages from heartbeat intervals, night after night. The method was trained on 8,898 manually scored laboratory nights (Topalidis et al., 2023, Sensors). What is evaluated is always the course over many nights. The same applies to the estimation of apnoea severity from the heart signal that we are working on: it, too, will be based on several nights.
The classification remains important: sleep² is approved in the EU as a medical device for the indication insomnia and does not diagnose sleep apnoea or other conditions.